mirror of
https://github.com/harvester/harvester-ui-extension.git
synced 2026-11-21 16:22:08 +08:00
4c60f8ec340ebef12d33d2bcdff477d8b93b6e3b
3
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
e66b61d0d1 |
feat: add the Kube-OVN VPC Egress Gateways page (#1263)
* feat: add the Kube-OVN VPC Egress Gateways page List, create and edit VpcEgressGateway resources under Overlay Networks > NAT & Internet, right below the NAT gateways, which are now labeled NAT Gateways. The form covers the VPC, replicas, internal and external subnets, SNAT policies, internal and external IPs, BFD and the bandwidth limit, and keeps the fields it does not show. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * feat: add the VPC BFD port and link the Egress Gateway BFD warning to it The VPC form gets a BFD Port tab with the enabled switch and its IP, which an Egress Gateway with BFD needs. The gateway form now checks the VPC's spec.bfdPort instead of a spec.bfd field that VPCs don't have, and its warning links to the VPC. Bandwidth also takes quantities such as 1Gi, and a gateway that only uses selectors no longer needs a policy. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * feat: check the Egress Gateway and BFD port against what Kube-OVN accepts Kube-OVN runs as a secondary CNI in Harvester, so an Egress Gateway's internal subnet has to sit on a virtual machine network and its external subnet on a network attachment; the subnet lists now offer only those. The internal and external IPs must be unique and inside their subnet, other than its gateway, and the two subnets must differ. Selectors don't work in that mode, so a gateway needs a policy again. Policies set with IP blocks show them, and BFD intervals hidden while BFD is off fall back to their defaults. Save stays disabled while either form is invalid, each field shows its own error, and a tab with errors is marked. The VPC's BFD port IP can't be in one of its subnets, its tab warns when it is turned off while gateways of the VPC use BFD, and the gateway's BFD warning opens the VPC's BFD Port tab in a new tab. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: show why Save is disabled on the Egress Gateway and VPC forms Every field that can block Save shows its own message once touched: the name, the VPC and both subnets, which have none when left empty. When the chosen VPC has no subnet on a virtual machine network, the Internal Subnet placeholder says so. A subnet can only be in one policy: the gateway leaves a source out of SNAT when any policy has SNAT off for it, so the same subnet in a second policy would silently ignore one of them. Enable SNAT explains what turning it off needs. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: keep one Egress Gateway policy for each SNAT setting Kube-OVN merges the sources of every policy with the same SNAT setting, so a second policy with SNAT on (or off) only adds to the first one. The form now flags it on the second policy, Add Policy adds the setting that isn't used yet and goes away once both exist, and the Policies tab says a gateway has at most two policies. Policies with IP blocks are left out of the check, since the form can't move those. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * refactor: ask for the Egress Gateway subnets with and without SNAT Kube-OVN puts the sources of every policy into two sets, with SNAT and without, and leaves a source out of SNAT when any policy has SNAT off for it. A list of policies with a checkbox each let the form build policies that only repeated or silently overrode each other, so the Policies tab now asks for those two sets: Subnets with SNAT and Subnets without SNAT, a subnet in one list only and at least one subnet in all. Saving writes one policy for each list that has subnets. Editing reads existing policies the way Kube-OVN applies them, so a subnet that was in both lands in Subnets without SNAT, and IP blocks set outside the form are kept and shown read-only. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * refactor: go back to the Egress Gateway policy list The VpcEgressGateway CRD and the issue describe policies as a list, each with snat and subnets, and Kube-OVN accepts any number of them: policies with the same SNAT setting just work together. The two subnet lists hid that shape and rewrote existing policies, and they couldn't mark "one of these two" as required. This puts back the policy list, where each policy needs a subnet and a subnet can be in one policy only, which is the one case that changes what the gateway does. The Policies tab now says how policies work together. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * refactor: ask for the Egress Gateway subnets with and without SNAT again Kube-OVN only uses which subnets have SNAT and which don't, so two lists, Subnets with SNAT and Subnets without SNAT, hold the same data as the policy list, are clearer to fill in, and can't build a policy that repeats or overrides another. Saving writes one policy for each list that has subnets. Neither list is marked required: the Policies tab says one subnet in either list is needed, and both lists show that message once touched while they're empty. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: show the Egress Gateway policy rule once for both subnet lists One subnet in either list is enough, but a warning on each list read as if both lists were required. The lists no longer show a warning; one message under them says to select at least one subnet in either list while both are empty, next to the tab mark and the disabled Save. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: say why the Egress Gateway subnet lists are empty The policy lists only offer subnets of the VPC chosen on the Basic tab, so before a VPC is chosen they were empty with no reason given. They now say to select a VPC on the Basic tab first, or that the chosen VPC has no subnets. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: make the Egress Gateway fields that need a VPC say so Internal Subnet and both policy lists only offer subnets of the chosen VPC, so they're disabled until a VPC is chosen and say to select one first. The policy lists keep their dropdown attached to the field, so it follows the field when a chip is removed instead of leaving a gap. The BFD intervals are labeled Receive Interval and Transmit Interval, which fit next to their unit, with a tooltip each. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: keep the external subnet out of Egress Gateway policies and check usable IPs Kube-OVN reroutes a policy's sources to the gateway, so the gateway's own external subnet as a source would send its outbound traffic back into it; the policy lists no longer offer it and the form flags it. Static IPs must also be usable addresses: Kube-OVN assigns from the network address + 1 to the broadcast address - 1, so those two are rejected along with the gateway. The policy rule is an error banner like the IP count rule, the BFD multiplier has its own message, the IP Addresses and Bandwidth instructions are hidden on the read-only page, and the VPC's warning about gateways that need its BFD port reads right for one gateway. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * chore: declare ipaddr.js, which the subnet model imports It was only installed as a dependency of webpack-dev-server. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * feat: support PrimaryCNI Egress Gateways Kube-OVN v1.17 can send a gateway's traffic out through the pod network when it isn't the primary CNI, as on Harvester. Such a gateway takes no external subnet, external IPs or bandwidth, so the form couldn't save one. The Basic tab now picks the external network, locked after creation, and hides the fields PrimaryCNI doesn't take. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> * fix: offer Primary CNI only when the cluster's CRD has it Kube-OVN v1.16, in Harvester v1.10.0-rc1 and older, has no externalNetworkMode and requires an external subnet, so a Primary CNI gateway was rejected there. The form reads the CRD's schema definition and only shows the External Network choice when the field exists. Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> --------- Signed-off-by: Marcelo Fukumoto <marcelo.fukumoto@suse.com> |
||
|
|
5406c08f76 |
perf: speed up the VM list with many VMs (#1189)
* perf: speed up the VM list with many VMs The VM list scanned whole store lists for every row and re-evaluated the same values per row on every render and sort. With several hundred VMs this blocked the browser on sorting and on every VM update. Performance: - look up launcher pods and migrations through shared indexes (namespace/name -> resource) instead of scanning per row; the indexes are computed per store list, so they stay in sync with in-place store updates - use the same migration lookup (getLatestMigration) in the VM model and on the VM detail page - look up PVCs, PVs, VMIs and restore backups by id - merge VMs and VMIs with a Set - evaluate the VM state once when sorting by state - check the unschedulable condition before the pod based state checks - cache feature flag results and per-schema/per-setting values that are the same for every row Bug fixes: - the launcher pod map was never rebuilt, because the store keeps the same array - pods, volumes and migrations of a VM with the same name in another namespace could be picked up The order of the volumes of a VM (vm.volumes) now follows the VM spec instead of the store order. Nothing depends on it. Measured in a synthetic setup, 100 rows per page, sorting by state (Chrome, dev build): - ~490 VMs, ~500 PVCs/PVs: 1.9 s -> 1.0 s - ~490 VMs, 600 PVs, 200 migrations: 6.0 s -> 0.7 s, main thread blocked during VM updates 78% -> 32% With few volumes the gain is much smaller (8-20%). Related to: https://github.com/harvester/harvester/issues/9513 Signed-off-by: Volker Theile <vtheile@suse.com> * fix: read VM data from the store of the resource instead of a fixed one The migrations of a VMI and the migration badge of the state column were read from the hardcoded `harvester` store. In the Rancher explorer (embedded and standalone) the data is loaded into the `cluster` store, so a running migration was shown neither in the VM state nor as badge. The VM model remembered the store of the current product in a module variable on first use and never updated it. The same model is used in the Harvester product (`harvester` store) and in the Rancher explorer (`cluster` store), and Rancher keeps the page loaded when going from the explorer of a Harvester cluster to Virtualization Management and into the Harvester product. The VM list then read the VMIs, launcher pods, volumes and restores from the wrong store, and running VMs were shown as Starting until the page was reloaded. Read the data from the store the resource lives in (`this.$getters`, in the formatter the store of the current product). In the Harvester product this is still the `harvester` store, so nothing changes there. Not covered: volume details like the lock icon of encrypted volumes. The explorer uses the generic Rancher PVC model, which does not know them, and settings based checks (feature flags, backup target) are not loaded there either. Related to: https://github.com/harvester/harvester/issues/11882 Signed-off-by: Volker Theile <vtheile@suse.com> --------- Signed-off-by: Volker Theile <vtheile@suse.com> |
||
|
|
71141b257a |
feat: Add a unit test target (jest) to the UI extension and run it in CI (#1192)
- Introduce test targets. - Adding additional tests. Related to: https://github.com/harvester/harvester/issues/11892 Signed-off-by: Volker Theile <vtheile@suse.com> |